Solar MPPT checker

Check a planned PV arrangement against controller voltage, current and power limits across expected temperatures. Unknown datasheet limits prevent a complete assessment.

Arrange your solar array

2 modules per string · 2 parallel strings

Conceptual grouping only; not a construction wiring diagram. Showing up to six panels and four strings. Confirm module and controller ratings below.

Module (STC)Module rating: Voc 38.9 V · Vmp 33 V · Isc 14 A · Imp 13.2 A. Review these against your datasheet.Design temperatures: cold -25 °C · warm 70 °C. Expand to review temperature coefficients.

Required for an operating-window pass. Voc coefficient is never a silent proxy pass.

Controller limitsAbsolute PV voltage limit — V · output limit — A. Blank ratings remain unknown.

Leave blank when unknown — overall pass requires known critical limits.

Battery
Inputs & assumptions

Results depend on the values and conditions you enter. Review the stated assumptions, equipment documentation and result limitations before making a purchase or starting installation.

Questions before you build
What is cold Voc?

Cold Voc estimates the highest open-circuit string voltage at your cold design temperature using the module Voc temperature coefficient. It must stay below the controller absolute maximum — not the MPPT operating maximum.

Is power clipping unsafe?

Only if you set max PV power to hard-limit. Oversize-clipping mode reports expected clipping. Exceeding absolute Voc or Isc is always a hard failure risk.

Do I need a brand?

No. Enter numbers from the module and controller datasheets. VanSchema never invents manufacturer limits.