Przejdź do treści

Electrical

Solar & battery calculator

Start with what you use. Build a balanced electrical plan for the way you travel.

Jump to resultsAll tools

Your energy picture

Detailed results

Daily use

735 Wh/day

Battery needed at 12 V

136.1 Ah

Charging − use

+789 Wh/day

Daily use
Daily charging

Battery sizing for 2 days without charging at 90% usable capacity. This is a recommended capacity, not a simulation of an installed battery. Charging uses the sources configured below.

Battery system voltage
W

Enter 0 if no array is planned. Adjust sun hours and other charging sources below.

Charging assumptions: DC–DC 30 A for 1 h/day; shore charger 20 A for 0 h/day; solar derating 75%.

01 / What will you run?

Updating results…

Add the equipment you use

Preset values are typical, editable starting points. Check the label on your equipment.

Adjust hours and watts directly. Open a device’s details for quantity, duty cycle and startup behaviour.

Compressor fridge (typical)

DC · 1 × 50 W · 33% running duty

— Wh/day

battery-side energy

Device details & assumptions

The fraction of the selected time the device actively draws its rated power. A cycling fridge may run for only part of the day.

LED lighting (typical)

DC · 1 × 10 W · 100% running duty

— Wh/day

battery-side energy

Device details & assumptions

The fraction of the selected time the device actively draws its rated power. A cycling fridge may run for only part of the day.

Laptop charger (typical)

AC · 1 × 65 W · 100% running duty

— Wh/day

battery-side energy

Device details & assumptions

The fraction of the selected time the device actively draws its rated power. A cycling fridge may run for only part of the day.

Charging, regional settings & calculation assumptions

Current assumptions: inverter efficiency 90%, usable battery fraction 90%, peak sun hours 4. Expand to inspect and edit all settings.

Calculation profile

ABYC E-11-derived planning · 105°C stranded copper. Country selection supplies installation references, not a compliance certificate.

Local installation reference: No local compliance profile verified; confirm with the relevant authority

Check local adoption and installation requirements. This tool does not certify an installation.

Equivalent full-power sun hours, not hours of daylight. Use a value for your actual travel location, season, flat roof and shading. No location lookup is used.

m
Inputs & assumptions

Results depend on the values and conditions you enter. Review the stated assumptions, equipment documentation and result limitations before making a purchase or starting installation.

Questions before you build
Why does the battery result exceed my daily consumption?

The bank must cover your chosen number of days and leave the unused portion required by your depth-of-discharge setting.

Does selecting a country estimate my solar yield?

No. A country can span very different climates. Enter local seasonal peak sun hours or monthly values for your actual travel plans.

Can I rely on the inverter rating for every motor load?

Check the appliance start-up demand, inverter surge duration and manufacturer instructions. The multiplier here is a planning allowance.